Series 3
DIGITAL FORCE GAUGES
User’s Guide
Zobrazit stránku 0
1 2 3 4 5 6 ... 22 23

Shrnutí obsahu

Strany 1 - DIGITAL FORCE GAUGES

Series 3 DIGITAL FORCE GAUGES User’s Guide

Strany 2 - TABLE OF CONTENTS

Series 3 Digital Force Gauges User’s Guide 9 Note: Set point indicators reference the displayed reading, not necessarily the current live lo

Strany 3

Series 3 Digital Force Gauges User’s Guide 10 Restart the computer before connecting a Mark-10 USB device. 5. After Windows as restarted,

Strany 4 - Caution!

Series 3 Digital Force Gauges User’s Guide 11 7. The next screen appears as follows: Click “Continue Anyway”. 8. The next, and final, sc

Strany 5 - 3 MECHANICAL SETUP

Series 3 Digital Force Gauges User’s Guide 12 Configure the baud rate and data format as required for the application. Default values are as

Strany 6 - 4 HOME SCREEN AND CONTROLS

Series 3 Digital Force Gauges User’s Guide 13 3. To escape the Calibration menu at any time, press ESCAPE. The display will appear as follo

Strany 7

Series 3 Digital Force Gauges User’s Guide 14 7. The display will appear as follows: Optionally exercise the load cell shaft se

Strany 8 - 7 DIGITAL FILTERS

Series 3 Digital Force Gauges User’s Guide 15 Press ENTER. 12. The display will appear as follows: Reverse the orientation of

Strany 9 - 8 SET POINT INDICATORS

Series 3 Digital Force Gauges User’s Guide 16 Ensure that the load is not swinging, oscillating, or vibrating in any manner. Then try again

Strany 10 - 9 COMMUNICATIONS

Series 3 Digital Force Gauges User’s Guide 17 Select Off for the backlight to be off upon powering on the gauge. Select On for the backl

Strany 11

Series 3 Digital Force Gauges User’s Guide 18 The default value is Real Time. 11.6 Information / Welcome Screen The following screen is

Strany 12

Series 3 Digital Force Gauges User’s Guide 1 Thank you… Thank you for purchasing a Mark-10 Series 3 digital force gauge, designed for tens

Strany 13 - 10 CALIBRATION

Series 3 Digital Force Gauges User’s Guide 19 12 SPECIFICATIONS 12.1 General Accuracy: ±0.3% of full scale ±1 digit Sampling rate: 2,

Strany 14

Series 3 Digital Force Gauges User’s Guide 20 12.3 Capacity, Resolution & Load Cell Deflection 12.4 Dimensions IN [MM

Strany 15

Series 3 Digital Force Gauges User’s Guide 21 NOTES:

Strany 16

Series 3 Digital Force Gauges User’s Guide 22 Mark-10 Corporation has been

Strany 17 - 11 OTHER SETTINGS

Series 3 Digital Force Gauges User’s Guide 2 1 OVERVIEW 1.1 List of included items Qty. Part No. Description M3-012 – M3-20 M3-50 – M3-

Strany 18

Series 3 Digital Force Gauges User’s Guide 3 accumulate in the sample during testing. Extra bodily protection should be worn if a destructiv

Strany 19

Series 3 Digital Force Gauges User’s Guide 4 3 MECHANICAL SETUP 3.1 Loading shaft orientation In order to accommodate a variety of testin

Strany 20 - 12 SPECIFICATIONS

Series 3 Digital Force Gauges User’s Guide 5 operator and others in the vicinity. If using a grip or fixture from a supplier other than Mark

Strany 21

Series 3 Digital Force Gauges User’s Guide 6 6 Mode The current measurement mode. Abbreviations are as follows: RT – Real Time

Strany 22

Series 3 Digital Force Gauges User’s Guide 7 5 OPERATING MODES Caution! In any operating mode, if the capacity of the instrument has be

Strany 23 - 32-1122

Series 3 Digital Force Gauges User’s Guide 8 Two filters are available: Current Reading – Applies to the peak capture rate of the instrum